Skip to article frontmatterSkip to article content
Site not loading correctly?

This may be due to an incorrect BASE_URL configuration. See the MyST Documentation for reference.

Station requirements and categorization

This section defines the minimum requirements for a station to be included in the list of multi-component solar irradiance monitoring stations. The most restricting criteria is that stations are required to measure at least two of the three irradiance components, such that the remaining component can be calculated.

Station categorization

Accepted stations are classified into two different categories: Tier 1 and Tier 2 stations, which are defined below.

Tier 1 stations

Tier 1 stations are defined as those that meet all of the following requirements (classification is according to ISO 9060):

Separate measurement of GHI is required for Tier 1 stations as most quality control procedures rely on comparing the measured GHI and GHI derived from direct and diffuse irradiance (closure equation). Stations in the BSRN network are examples of Tier 1 stations.

Tier 2 stations

Tier 2 stations are defined as those that do not meet the Tier 1 requirements but meet one of the following specifications:

Non-qualifying stations

Stations that only measure GHI are not considered, which is in part because there are thousands of such stations worldwide and there are limited methods for assessing the quality of the measurements. Also, stations that measure DHI using a manually adjusted shadow band are generally not considered, as such measurements are notoriously unreliable due to the shadow band having to be adjusted every few days.